HODINFO is a collaborative think tank. We are an International group comprised of inventors, scientist, mechanics, tinkerers, fabricators, and out of the box thinkers. Our mission is to find innovative solutions to the problems that primarily limit the production and delivery of H2. As the world wakes up to the idea of using hydrogen it also becomes clear that immense infrastructure initiatives will be required to make it happen. If adequate solutions can be found to support HOD systems then the world can remove great and costly limitations on future applications. It is important to realize that the future is not just Hydrogen, it's Hydrogen-on-Demand.

Dr. Ralston Methadone
Share

Dr. Ralston Methadone's Friends

  • Richard Collins
  • Raimis Juodvalkis
  • Robert Bley
  • Russell Nagode
  • skysabre
  • James Morehead
  • Pat Johnson
  • don
  • gabet123

Dr. Ralston Methadone's Discussions

Forget gas, batteries — pee is new power source

Started this discussion. Last reply by Michael Scharna Apr 19, 2010. 7 Replies

Forget gas, batteries — pee is new power sourceScientists can create cheap hydrogen from urine for use in fuel cells…Continue

Plasma Water Electrolysis - Phillip M. Kanarev

Started this discussion. Last reply by Mike Hingle Dec 18, 2009. 1 Reply

Electrolytic processes are known for a long time, and they are widely used in chemical industry.Plasma electrolytic processes have been found quite recently, that’s why there is neither physical, nor…Continue

JP2004059977 - Method and Apparatus for Generating Hydrogen Gas - Tadahiko Mizuno

Started this discussion. Last reply by skysabre Dec 18, 2009. 3 Replies

Abstract : PROBLEM TO BE SOLVED: To provide a method for generating a hydrogen gas with a high efficiency by continuously and directly pyrolyzing water with a satisfactory controllability. SOLUTION:…Continue

ON THE WAY TO PULSE POWER ENGINEERING Ph. M. Kanarev

Started this discussion. Last reply by Raimis Juodvalkis Dec 13, 2009. 1 Reply

Abstract: The direct experiment results are presented. They show falseness of a determination of average power consumed in the form of regular pulses by means of a single record of duty ratio of…Continue

 

Dr. Ralston Methadone's Page

Latest Activity

charles ware replied to Dr. Ralston Methadone's discussion 'Confirmation of anomalous hydrogen generation by plasma electrolysis'
"I have always thought that the work of Dr. Mizuno was really interesting. Too bad it seems like it has largely been ignored. He has published a number of papers along these lines. Another is: http://lenr-canr.org/acrobat/MizunoTanomalouse.pdf In…"
Oct 4, 2016
Joshua favorited Dr. Ralston Methadone's profile
Oct 3, 2016
gabet123 replied to Dr. Ralston Methadone's discussion 'Confirmation of anomalous hydrogen generation by plasma electrolysis'
"Interesting looking cell design."
Oct 3, 2016
gabet123 left a comment for Dr. Ralston Methadone
"Your interaction number 26"
Dec 7, 2011
James Morehead and Dr. Ralston Methadone are now friends
Dec 3, 2010
Pat Johnson left a comment for Dr. Ralston Methadone
"Good to hear that someone else in Olympia is doing hho. I'm semi retired so my schedule is open most of the time. 360-790-6943 Pat"
Sep 5, 2010
Dr. Ralston Methadone joined gabet123's group
Thumbnail

Meyer Research Group

This group is dedicated to the work of Stanley Meyer.
Sep 3, 2010
Michael Scharna replied to Dr. Ralston Methadone's discussion 'Forget gas, batteries — pee is new power source'
Apr 19, 2010
skysabre replied to Dr. Ralston Methadone's discussion 'Contact glow discharge electrolysis: a study of its chemical yields in aqueous inert-type electrolytes'
"Dr. Ralston - I suspect Kanarev used a half-wave rectifier. His paper on Pulse Wave Engineering seems to suggest this. Is this true?"
Apr 14, 2010
skysabre replied to Dr. Ralston Methadone's discussion 'Contact glow discharge electrolysis: a study of its chemical yields in aqueous inert-type electrolytes'
"I wish Dr. Ralston shows up. Some important questions are emerging already."
Apr 11, 2010
skysabre replied to Dr. Ralston Methadone's discussion 'Contact glow discharge electrolysis: a study of its chemical yields in aqueous inert-type electrolytes'
"Thanks, Peter! I'm making a new diagram, and will post in the Contact Glow Group discussion."
Apr 10, 2010
Robert Bley replied to Dr. Ralston Methadone's discussion 'Contact glow discharge electrolysis: a study of its chemical yields in aqueous inert-type electrolytes'
"Thanks for helping out Peter. I am using the full power output from my transformer and it is well over 1000 volts and probably closer to 2000v. I put tap water in it this morning and made a nasty cocktail in about 30 seconds. I have been putting…"
Apr 10, 2010
Peter Kiproff replied to Dr. Ralston Methadone's discussion 'Contact glow discharge electrolysis: a study of its chemical yields in aqueous inert-type electrolytes'
"Hi Skysabre This hookup is correct. Take all safe precautions, remember you are referanced to ground from the mains. make sure your transformer has proper rated fuse on primary to keep the magic smoke from getting out. Phase of transformer useing…"
Apr 10, 2010
skysabre replied to Dr. Ralston Methadone's discussion 'Contact glow discharge electrolysis: a study of its chemical yields in aqueous inert-type electrolytes'
"Thanks for the info Peter! Please look this over. This design is based on what you wrote. Will this work? The line voltage here is 220VAC. I'm thinking of using one source at 220, and another through a step down transformer at 110 VAC. In…"
Apr 10, 2010
Peter Kiproff replied to Dr. Ralston Methadone's discussion 'Contact glow discharge electrolysis: a study of its chemical yields in aqueous inert-type electrolytes'
"If you use bridge on 220 VAC you should mult by 1.4 to get DC just over 300 VDC 600V 25A bridge is about $4, it has a single mounting hole for #10 screw onto heat sink. connections are push on or solder. Note: as long as you use transformers you can…"
Apr 10, 2010
skysabre replied to Dr. Ralston Methadone's discussion 'Contact glow discharge electrolysis: a study of its chemical yields in aqueous inert-type electrolytes'
"I'm using 6A rectifiers. They're hardly warm after the tests. They're cheap too - $1.50 each. I had 600PIV 60A diodes on stand by, but I returned them. They cost $15.00 each. BTW. My transformer got burnt bad. Now I may have to limit…"
Apr 9, 2010

Profile Information

Location
USA
What is your HOD level of experience?
Intermediate Builder
Do you have a website about HOD technology? Please link to HODINFO also!
http://hydrogen23.blogspot.com

Comment Wall (4 comments)

You need to be a member of HODINFO to add comments!

Join HODINFO

At 5:04pm on December 7, 2011, gabet123 said…

Your interaction number 26

At 2:20pm on September 5, 2010, Pat Johnson said…
Good to hear that someone else in Olympia is doing hho. I'm semi retired so my schedule is open most of the time. 360-790-6943 Pat
At 6:59am on December 13, 2009, Raimis Juodvalkis said…
Hi, I met Kanarev in person this spring. In order to send to you his patent you need to provide your mail address. Please mail me at raimis@me.com.
Regards, Raimis
At 6:13pm on December 5, 2009, gabet123 said…
Welcome aboard! I think you would benefit from Joining the TAH group. Also feel free to create your own groups.
 
 
 

*** Translate HODINFO ***

Archive this page

© 2017   Created by gabet123.   Powered by

Badges  |  Report an Issue  |  Privacy Policy  |  Terms of Service

Live Chat